Hilfe bei Abluft, zu hohe RLF. Jemand Tipps?

Grow4ever
Grow4everstarted grow question 17d ago
Have two tents 120x60 and 60x60 with separate exhaust each, 380 m³/h, 310 m³/h for a total of 1,728 m³. Lung space is regulated to 50% with dehumidifier, nevertheless 65-75% rlf in both tents. Exhaust blows into a Y directly out of the window, tent openings are wide open with exhaust grilles.
Solved
2 likes
Altitonans_Fulmen
Altitonans_Fulmenanswered grow question 18d ago
Can't have two exhaust ducts connecting to the same size y duct and expect same flow, essentially will reduce the flow of both, unless both tent exhaust at same time some it will simply reverse back hot air from one to another. Your exhaust dictates the size and rate of flow, but many things in the tent will add resistance to that flow. If you have carbon filter you will need to double the general size of you intake, opening all the bottom flaps is not an answer as you will not create a negative pressure required to reduce the ambient rh%. Negative pressure requires just a little more going out than coming in, enough that the bars begin to bend in but not enough so that they wreck the tent. Done correctly the exhausts will slowly pump out slightly more than what comes in. Rh% will slowly decline as the tent environment becomes a semi closed loop. Most likely either have no Negative pressure from "keeping vents open" to help with airflow or you have added so much resistance (closed off intakes with "not enough airflow") your intake cannot bring in enough air in order to exchange and cool, heat and moisture accumulate faster than your air flow, air exchange must outpaced latent heat during the day and outpaced cellular respiration at night. Increase intake and apply correct ratio to apply correct Negative pressure. Fix the Y junction to 8" instead of the 4" or 6" .
2 likes
Complain
Selected By The Grower
UDUDUDUDU
UDUDUDUDUanswered grow question 17d ago
Yeap' it will work, proper configuration is with a fan pulling after da connecting junction. 2 low rpms inside da tent with a 3rd higher rev in da pipe -555.
1 like
Complain
Organoman
Organomananswered grow question 17d ago
Get rid of the "Y" and have two seperate exhaust ducts, one for each tent..............that should solve your issue.
1 like
Complain
Wojkers
Wojkersanswered grow question 18d ago
If your room is around 50% but both tents sit at 65-75%, I’d check how much air your exhausts are actually moving. The Y connection could be what’s limiting the airflow if both fans are pushing into one same sized duct. I’d disconnect the Y for a test and let both exhausts vent separately. If the RH drops, you probably found the problem
1 like
Complain
thcishcrud
thcishcrudanswered grow question 18d ago
Deine Werte sehen ja gar nicht mal so schlimm aus und ein perfektes System wird es nie geben aus dem heimgarten. Aber wenn beide über dein Fenster ausblasen musst du auch den Außendruck in Betracht ziehen und wie der Wind an dieser Hauswand lang zieht und so auch Überdruck erzeugt und gegen deine Lüfter drück. Und eben erst noch diesen Artikel gelesen: https://softsecrets.com/de/artikel/warum-ist-unterdruck-im-growroom-wichtig
1 like
Complain
00110001001001111O
00110001001001111Oanswered grow question 18d ago
Just reduce the lung room a bit more or increase exhaust power... Rate of moisture released in the tents will keep increasing until mid flower, then it flattens out. What averages out is predictable.. You'll know how to adjust if the ambient conditions change. Lung room may need to be 40% to get the right mix in the tents, or like i said, beefing up the exhaust will also help lower the average anytime the lung room is lower than the tents. Maybe your house RH spikes in late summer and may need a different approach. 6" duct has a max CFM approaching 600. The soft stuff is a bit lower than the rigid ducts. I've done this before on my first grow setup with 2 tents. It worked fine, but i did have some light pollution caused by it. Even with a louvered port. I didn't bend the duct enough... if the port faces the sun at any time during lights off, it's a concern.
1 like
Complain
Green_Claws
Green_Clawsanswered grow question 18d ago
If the extractor is inside the tent to Push the air out moving it no near the window and suck the air out. Heat the lung room up and it will bring rh down in the tent
1 like